快活林资源网 Design By www.csstdc.com

WinXP,Win7,Win8
复制代码 代码如下:
'原创内容转载、引用代码核心部分请注明出处
硬盘读写统计.vbs
If (Lcase(Right(Wscript.FullName,11)) = "wscript.exe") Then
   CreateObject("WScript.Shell").Run("%Comspec% /C " &Chr(34)&"mode con cols=52 lines=22" &"&Title  硬盘读写统计.vbs  By: FastSLZ  PCEVA Or BatHome   &&Cscript.exe //NoLogo  "&Chr(34)& Wscript.ScriptFullName &Chr(34)&Chr(34)),3:Set WMI = Nothing:Wscript.Quit
End If
Dim WMI,vName,IDE,cPPP,sNow
Input = 1:InputS = Input*980
On Error Resume Next
Set WMI = GetObject("winmgmts:{impersonationLevel=impersonate}!\\.\root\cimv2")
Set IDE = WMI.ExecQuery("Select * from Win32_DiskDrive WHERE InterfaceType='IDE'")
Set cPPP = WMI.ExecQuery("SELECT * FROM Win32_PerfRawData_PerfDisk_PhysicalDisk WHERE Name <> '_Total'")
For Each oIDE In IDE
    For i = 0 To IDE.Count  
        Select Case oIDE.Index
            Case i
               For Each oPPP In cPPP
                   If InStr(oPPP.Name, i) Then vName = oPPP.Name
               Next
               Select Case i
                   Case 0 Disk0=oIDE.Caption&" "&oIDE.FirmwareRevision:Size0=oIDE.Size:DskP0=vName
                   Case 1 Disk1=oIDE.Caption&" "&oIDE.FirmwareRevision:Size1=oIDE.Size:DskP1=vName
                   Case 2 Disk2=oIDE.Caption&" "&oIDE.FirmwareRevision:Size2=oIDE.Size:DskP2=vName
                   Case 3 Disk3=oIDE.Caption&" "&oIDE.FirmwareRevision:Size3=oIDE.Size:DskP3=vName
                   Case 4 Disk4=oIDE.Caption&" "&oIDE.FirmwareRevision:Size4=oIDE.Size:DskP4=vName
                   Case 5 Disk5=oIDE.Caption&" "&oIDE.FirmwareRevision:Size5=oIDE.Size:DskP5=vName
               End Select

        End Select
    Next
Next
Set cPPP = Nothing:Set IDE= Nothing
If Disk0 <> "" Then WScript.Echo Left(DskP0,1)&":"&vbTab& Disk0 &vbTab _
                  &vbCrLf&vbTab&"厂商容量:"&Round(Size0/1000000000) &"GB" _
                  &vbCrLf&vbTab&"实际容量:"&Round(Size0/1073741824,2) &"GB" _
                  &vbCrLf&vbTab&"分区状态:"&Right(DskP0,Len(DskP0)-2)
If Disk1 <> "" Then WScript.Echo Left(DskP1,1)&":"&vbTab& Disk1 &vbTab _
                  &vbCrLf&vbTab&"厂商容量:"&Round(Size1/1000000000) &"GB" _
                  &vbCrLf&vbTab&"实际容量:"&Round(Size1/1073741824,2) &"GB" _
                  &vbCrLf&vbTab&"分区状态:"&Right(DskP1,Len(DskP1)-2)
If Disk2 <> "" Then WScript.Echo Left(DskP2,1)&":"&vbTab& Disk2 &vbTab _
                  &vbCrLf&vbTab&"厂商容量:"&Round(Size2/1000000000) &"GB" _
                  &vbCrLf&vbTab&"实际容量:"&Round(Size2/1073741824,2) &"GB" _
                  &vbCrLf&vbTab&"分区状态:"&Right(DskP2,Len(DskP2)-2)
If Disk3 <> "" Then WScript.Echo Left(DskP3,1)&":"&vbTab& Disk3 &vbTab _
                  &vbCrLf&vbTab&"厂商容量:"&Round(Size3/1000000000) &"GB" _
                  &vbCrLf&vbTab&"实际容量:"&Round(Size3/1073741824,2) &"GB" _
                  &vbCrLf&vbTab&"分区状态:"&Right(DskP3,Len(DskP3)-2)
If Disk4 <> "" Then WScript.Echo Left(DskP4,1)&":"&vbTab& Disk4 &vbTab _
                  &vbCrLf&vbTab&"厂商容量:"&Round(Size4/1000000000) &"GB" _
                  &vbCrLf&vbTab&"实际容量:"&Round(Size4/1073741824,2) &"GB" _
                  &vbCrLf&vbTab&"分区状态:"&Right(DskP4,Len(DskP4)-2)
If Disk5 <> "" Then WScript.Echo Left(DskP5,1)&":"&vbTab& Disk5 &vbTab _
                  &vbCrLf&vbTab&"厂商容量:"&Round(Size5/1000000000) &"GB" _
                  &vbCrLf&vbTab&"实际容量:"&Round(Size5/1073741824,2) &"GB" _
                  &vbCrLf&vbTab&"分区状态:"&Right(DskP5,Len(DskP5)-2)
WScript.Echo "↑请输入要监控的硬盘编号,并按回车键"
stdInput = WScript.StdIn.Readline
stdInput=Left(UCase(stdInput),1)
If stdInput > "5" Or stdInput < "0" Then MsgBox "输入错误" :WScript.Quit
If InStr(DskP0, stdInput) Then Call Network(Disk0,Size0,DskP0)
If InStr(DskP1, stdInput) Then Call Network(Disk1,Size1,DskP1)
If InStr(DskP2, stdInput) Then Call Network(Disk2,Size2,DskP2)
If InStr(DskP3, stdInput) Then Call Network(Disk3,Size3,DskP3)
If InStr(DskP4, stdInput) Then Call Network(Disk4,Size4,DskP4)
If InStr(DskP5, stdInput) Then Call Network(Disk5,Size5,DskP5)

Sub Network(Disks,Sizes,DskPs)
sNow=Now
Do
Dim A
'WScript.Echo "已运行"&Ts\3600&"小时"&(Ts mod 3600)\60&"分钟"&(Ts mod 3600) mod 60&"秒"
Set A = WMI.ExecQuery("Select * from Win32_PerfRawData_PerfDisk_PhysicalDisk Where Name='"&DskPs&"'")
For Each B In A
    R1 = B.DiskReadBytesPersec
    W1 = B.DiskWriteBytesPersec
    If RA0 = "" Then RA0 = B.DiskReadBytesPersec Else RA1 = R1 End If
    If WA0 = "" Then WA0 = B.DiskWriteBytesPersec Else WA1 = W1 End If
Next
Set A = Nothing
WScript.Sleep(InputS)
Set A = WMI.ExecQuery("Select * from Win32_PerfRawData_PerfDisk_PhysicalDisk Where Name='"&DskPs&"'")
For Each B In A
    R2 = B.DiskReadBytesPersec
    W2 = B.DiskWriteBytesPersec
Next
Set A = Nothing
WScript.Echo Disks &" " &Round(Sizes/1073741824) &"GB" &vbCrLf _
      &"实时读取:" & CheckSize((R2-R1)/Input) &"/s" &vbCrLf _
      &"实时写人:" & CheckSize((W2-W1)/Input) &"/s"&vbCrLf _
      &"脚本累计读取:" & CheckSize(RA1-RA0) &vbCrLf _
      &"脚本累计写入:" & CheckSize(WA1-WA0) &vbCrLf _
      &"开机累计读取:" & CheckSize(R1) &vbCrLf _
      &"开机累计写入:" & CheckSize(W1) &vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf _
      &"已运行"&Ts\3600&"小时"&(Ts mod 3600)\60&"分钟"&(Ts mod 3600) mod 60&"秒"
Ts=DateDiff("s", sNow, Now)'Ts=TS+1
Loop
End Sub

Function CheckSize(SZ)
On Error Resume Next
If SZ => 1073741824 Then
   SZ = FormatNumber(Round(SZ/1073741824,2))&" GB"
   ElseIf SZ => 1048576 Then
   SZ = FormatNumber(Round(SZ/1048576,2))&" MB"
   ElseIf SZ => 1024 Then
   SZ = FormatNumber(Round(SZ/1024,2))&" KB"
Else
   SZ = "0"&FormatNumber(Round(SZ/1024,2)) & " KB"
End If
CheckSize=Right("      " & SZ,10)
End Function

分区读写统计.vbs
复制代码 代码如下:
'原创内容转载、引用代码核心部分请注明出处
If (Lcase(Right(Wscript.FullName,11)) = "wscript.exe") Then
   CreateObject("WScript.Shell").Run("%Comspec% /C " &Chr(34)&"mode con cols=52 lines=22" &"&Title  分区读写统计.vbs  By: FastSLZ  PCEVA Or BatHome   &&Cscript.exe //NoLogo  "&Chr(34)& Wscript.ScriptFullName &Chr(34)&Chr(34)),3:Set WMI = Nothing:Wscript.Quit
End If
Input = 1:InputS = Input*1000
Dim WMI,vName,IDE,cPPP,sNow
On Error Resume Next
Set WMI = GetObject("winmgmts:{impersonationLevel=impersonate}!\\.\root\cimv2")

Set IDE = WMI.ExecQuery("Select * from Win32_DiskDrive WHERE InterfaceType='IDE'")
Set cPPP = WMI.ExecQuery("SELECT * FROM Win32_PerfRawData_PerfDisk_PhysicalDisk WHERE Name<>'_Total'")
For Each oIDE In IDE
    For i = 0 To IDE.Count  
        Select Case oIDE.Index
            Case i
               For Each oPPP In cPPP
                   If InStr(oPPP.Name, i) Then vName = oPPP.Name
               Next
               Select Case i
                   Case 0 Disk0=oIDE.Caption&" "&oIDE.FirmwareRevision:Size0=oIDE.Size:DskP0=vName
                   Case 1 Disk1=oIDE.Caption&" "&oIDE.FirmwareRevision:Size1=oIDE.Size:DskP1=vName
                   Case 2 Disk2=oIDE.Caption&" "&oIDE.FirmwareRevision:Size2=oIDE.Size:DskP2=vName
                   Case 3 Disk3=oIDE.Caption&" "&oIDE.FirmwareRevision:Size3=oIDE.Size:DskP3=vName
                   Case 4 Disk4=oIDE.Caption&" "&oIDE.FirmwareRevision:Size4=oIDE.Size:DskP4=vName
                   Case 5 Disk5=oIDE.Caption&" "&oIDE.FirmwareRevision:Size5=oIDE.Size:DskP5=vName
               End Select

        End Select
    Next
Next
Set cPPP = Nothing:Set IDE= Nothing
If Disk0 <> "" Then DskP=Right(DskP0,Len(DskP0)-2):WScript.Echo Left(DskP0,1)&":"&vbTab& Disk0 &vbTab _
                  &vbCrLf&vbTab&"分区状态:"&Right(DskP0,Len(DskP0)-2)
If Disk1 <> "" Then DskP=DskP&" "&Right(DskP1,Len(DskP1)-2):WScript.Echo Left(DskP1,1)&":"&vbTab& Disk1 &vbTab _
                  &vbCrLf&vbTab&"分区状态:"&Right(DskP1,Len(DskP1)-2)
If Disk2 <> "" Then DskP=DskP&" "&Right(DskP2,Len(DskP2)-2):WScript.Echo Left(DskP2,1)&":"&vbTab& Disk2 &vbTab _
                  &vbCrLf&vbTab&"分区状态:"&Right(DskP2,Len(DskP2)-2)
If Disk3 <> "" Then DskP=DskP&" "&Right(DskP3,Len(DskP3)-2):WScript.Echo Left(DskP3,1)&":"&vbTab& Disk3 &vbTab _
                  &vbCrLf&vbTab&"分区状态:"&Right(DskP3,Len(DskP3)-2)
If Disk4 <> "" Then DskP=DskP&" "&Right(DskP4,Len(DskP4)-2):WScript.Echo Left(DskP4,1)&":"&vbTab& Disk4 &vbTab _
                  &vbCrLf&vbTab&"分区状态:"&Right(DskP4,Len(DskP4)-2)
If Disk5 <> "" Then DskP=DskP&" "&Right(DskP5,Len(DskP5)-2):WScript.Echo Left(DskP5,1)&":"&vbTab& Disk5 &vbTab _
                  &vbCrLf&vbTab&"分区状态:"&Right(DskP5,Len(DskP5)-2)
WScript.Echo vbCrLf&"请输入"&DskP&"中任意一个盘符"
stdInput = WScript.StdIn.Readline
stdInput=Left(UCase(stdInput),1)
If InStr(DskP,stdInput) Then Call Network(stdInput&":")
Sub Network(DskPs)
sNow=Now
Do
Dim A
Set A = WMI.ExecQuery("Select * from Win32_PerfRawData_PerfDisk_LogicalDisk Where Name = '"& DskPs &"'")
For Each B In A
    R1 = B.DiskReadBytesPersec
    W1 = B.DiskWriteBytesPersec
    If RA0 = "" Then RA0 = B.DiskReadBytesPersec Else RA1 = R1 End If
    If WA0 = "" Then WA0 = B.DiskWriteBytesPersec Else WA1 = W1 End If
Next
Set A = Nothing
WScript.Sleep(InputS)
Set A = WMI.ExecQuery("Select * from Win32_PerfRawData_PerfDisk_LogicalDisk Where Name = '"& DskPs &"'")
For Each B In A
    R2 = B.DiskReadBytesPersec
    W2 = B.DiskWriteBytesPersec
Next
Set A = Nothing
WScript.Echo "监控分区:" &DskPs &vbCrLf _
      &"实时读取:" & CheckSize((R2-R1)/Input) &"/s" &vbCrLf _
      &"实时写人:" & CheckSize((W2-W1)/Input) &"/s"&vbCrLf _
      &"脚本累计读取:" & CheckSize(RA1-RA0) &vbCrLf _
      &"脚本累计写入:" & CheckSize(WA1-WA0) &vbCrLf _
      &"开机累计读取:" & CheckSize(R1) &vbCrLf _
      &"开机累计写入:" & CheckSize(W1) &vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf&vbCrLf _
      &"已运行"&Ts\3600&"小时"&(Ts mod 3600)\60&"分钟"&(Ts mod 3600) mod 60&"秒"
Ts=DateDiff("s", sNow, Now)'Ts=TS+1
Loop
End Sub

Function CheckSize(SZ)
On Error Resume Next
If SZ => 1073741824 Then
   SZ = FormatNumber(Round(SZ/1073741824,2))&" GB"
   ElseIf SZ => 1048576 Then
   SZ = FormatNumber(Round(SZ/1048576,2))&" MB"
   ElseIf SZ => 1024 Then
   SZ = FormatNumber(Round(SZ/1024,2))&" KB"
Else
   SZ = "0"&FormatNumber(Round(SZ/1024,2)) & " KB"
End If
CheckSize=Right("      " & SZ,10)
End Function

快活林资源网 Design By www.csstdc.com
广告合作:本站广告合作请联系QQ:858582 申请时备注:广告合作(否则不回)
免责声明:本站资源来自互联网收集,仅供用于学习和交流,请遵循相关法律法规,本站一切资源不代表本站立场,如有侵权、后门、不妥请联系本站删除!
快活林资源网 Design By www.csstdc.com

稳了!魔兽国服回归的3条重磅消息!官宣时间再确认!

昨天有一位朋友在大神群里分享,自己亚服账号被封号之后居然弹出了国服的封号信息对话框。

这里面让他访问的是一个国服的战网网址,com.cn和后面的zh都非常明白地表明这就是国服战网。

而他在复制这个网址并且进行登录之后,确实是网易的网址,也就是我们熟悉的停服之后国服发布的暴雪游戏产品运营到期开放退款的说明。这是一件比较奇怪的事情,因为以前都没有出现这样的情况,现在突然提示跳转到国服战网的网址,是不是说明了简体中文客户端已经开始进行更新了呢?